Analyze and test

The diagnostics tool is used to analyze and test the SmartNICs. The test result includes sensors, SDRAM information, and time synchronization information. A traffic test is also performed. In order to run the test, you need to loop port 0 and port 1, port 2 and port 3 etc. as shown in the figure below.

The diagnostics tool is under the installation directory on Windows e.g. C:\Program Files\Napatech3\bin.

Cabling to run the diagnostics tool

Page-14 Sheet.1 Line-curve connector Line-curve connector.3

Example

The following example is the output of the diagnostics tool on Linux.

# /opt/napatech3/bin/diagnostics -a 1
diagnostics (v. 2.8.2.0-97c1c)
==============================================================================
System: 2.8.2.0
------------------------------------------------------------------------------
Adapters:  2
Ports:     4
==============================================================================
Adapter 1  NT20E2-CAP Capture Network Adapter PCIe Gen2 2x10Gb SFP+
------------------------------------------------------------------------------
              Sensor  Unit     Limit   Limit   Value   Sensor   Value   Value
              type               low    high   curr.    state     min     max
------------------------------------------------------------------------------
FPGA          Temp.   [C]        0.0    90.0    46.0   Normal    45.0    47.0
FAN           Speed   [RPM]     5270    7440    6322   Normal    6320    6348
Main PSU 1    Temp.   [C]      -40.0   125.0    52.0   Normal    52.0    57.0
Main PSU 2    Temp.   [C]      -40.0   125.0    57.0   Normal    52.0    57.0
Front PSU     Temp.   [C]      -40.0   125.0    42.0   Normal    37.0    42.0
Front PCB     Temp.   [C]        0.0    85.0    51.5   Normal    49.5    52.5
NT20E2        Power   [W]                       23.1   Normal    22.1    23.5
FPGA          Power   [W]                       11.8   Normal    10.7    13.6
DDR3          Power   [W]                        3.3   Normal     3.3     3.3
PHY           Power   [W]                        1.3   Normal     0.7     1.7
NIM PWR A     Power   [W]                        2.0   Normal     0.0     2.0
NIM PWR B     Power   [W]                        0.0   Normal     0.0     2.0
------------------------------------------------------------------------------
Port 2:
SFP+          Temp.   [C]      -13.0    78.0    50.5   Normal    46.6    51.3
Supply        Voltage [V]       2.90    3.70    3.25   Normal    3.24    3.25
Tx Bias       Current [mA]      2.00   11.80    8.81   Normal    8.71    8.86
Tx(AVG)       Power   [uW]       158     832     598   Normal     592     606
Rx(AVG)       Power   [uW]        10    1000     580   Normal       0     590
------------------------------------------------------------------------------
Port 3:
SFP+          Temp.   [C]       -5.0    75.0    47.0   Normal    44.0    47.8
Supply        Voltage [V]       2.97    3.63    3.22   Normal    3.21    3.22
Tx Bias       Current [mA]      2.00   10.50    6.51   Normal    6.34    6.54
Tx(AVG)       Power   [uW]        74    1412     601   Normal     597     604
Rx(AVG)       Power   [uW]        41    1585     583   Normal       2     592
------------------------------------------------------------------------------

Analyzing SDRAM:
------------------------------------------------------------------------------
SDRAM Present Yes
SDRAM type : DDR3
SDRAM size : 1GB
------------------------------------------------------------------------------
Timesync information:
------------------------------------------------------------------------------
PTP timesync available         : No
Timesync connector Ext1        : NttsIn
Timesync connector Int1        : None
Timesync connector Int2        : None
Clock reference priority       : NT-TS(Ext1), FreeRun
Current clock reference        : FreeRun
Frequency reference priority   : FreeRun
Current frequency reference    : FreeRun
Timesync clock adjustmentmode  : 1
TimeSync time jump threshold   : 1
Configured NT-TS in-sync limit : 5000 (ns)
Configured OS in-sync limit    : 10000 (ns)
Configured PPS in-sync limit   : 5000 (ns)
Adapter clock sampled timestamps:
None
------------------------------------------------------------------------------
Traffic test:
------------------------------------------------------------------------------
Receive port 2
Transmit port 3
Sending packet: 10000 of 10000
Received 10000 packets. Success
Receive port 3
Transmit port 2
Sending packet: 10000 of 10000
Received 10000 packets. Success
==============================================================================