Monitor the status
Please use the monitoring tool to monitor the time synchronization
status as shown below. The monitoring tool is under the installation
directory on Windows e.g. C:\Program Files\Napatech3\bin.
# /opt/napatech3/bin/monitoringThen, press the X key to go to the time synchronization monitoring. The monitoring area displays whether each SmartNIC is in synchronization or not, the time stamp format, and each connector’s configuration.
┌─────────────────────── monitoring (v. 2.8.2.0-97c1c) ────────────────────────┐ │ Adapter In-Sync TimeStamp Int1 Int2 Ext1 │ │ 0 yes Native Unix None None None │ │ 1 N/A Native Unix None None NttsIn │ └──────────────────────────────────────────────────────────────────────────────┘ ┌────────────────────────────────── Timesync ──────────────────────────────────┐ │ Overview │ │ Adapter time (UTC) : Wed 29-Oct-2014 17:55:13.872954600 │ │ Reference priority : OsTime Freq priority: FreeRun │ │ Current reference : OsTime Current freq : FreeRun │ │ Skew (ns) : 6 │ │ Clock rate adjustment : -23436 │ │ │ │ Clock hard reset : Enabled │ │ Time offset (ns) : 0 │ │ │ └──────────────────────────────────────────────────────────────────────────────┘ Reset 0Overview 1Sampling 2PPS stat 3TS stat 4External status Quit Sensors Port stat Color stat IEEE 1588 PTP DStream FDump
Select a SmartNIC
You can select a SmartNIC by placing the cursor using the arrow UP and DOWN keys in order to monitor each SmartNIC’s time synchronization status. Each SmartNIC’s time synchronization information is shown above in the Timesync area, including the current SmartNIC time.
Run the monitoring tool on Windows
The monitoring tool is under the installation directory on Windows e.g. C:\Program Files\Napatech3\bin. You can run the monitoring tool on Windows as shown in the command example below.
C:\Program Files\Napatech3\bin>monitoring
Please refer to DN-0449 for more information about the monitoring tool.