In this chapter
This chapter describes the monitoring capabilities of the SmartNICs. The parameters described in the chapter can be monitored from the application through the API or by using the monitoring tool (see DN-0449).
Monitoring parameters can be divided into optical module parameters and SmartNIC parameters. They consist of both sensor parameters and state parameters.
Optical module parameters
Module | SmartNICs | Mandatory Parameters | Optional Parameters |
---|---|---|---|
QSFP28 |
NT200A02-2×100/40, NT200A01-2×100/40, NT200A01-2×100 |
|
|
CFP4 |
NT200C01-2×100, NT100E3-1-PTP |
|
|
QSFP+ |
NT200A02-2×100/40, NT200A02-2×40/8×10, NT200A02-8×10/2×40, NT200A01-2×100/40, NT200A01-2×40, NT200A01-2×25/10/2×40, NT200A01-8×10/2×40, NT80E3-2-PTP, NT80E3-2-PTP-8×10/2×40, Intel® PAC A10 GX |
|
|
SFP28 |
NT200A01-2×25/10/2×40 (with a pluggable module adapter (PMA – see DN-0515) enabling SFP28 and SFP+ modules to be plugged into a QSFP28 port) |
|
|
SFP+ |
NT200A02-2×40/8×10, NT200A02-8×10/2×40, NT200A01-2×25/10/2×40 (with a pluggable module adapter (PMA – see DN-0515) enabling SFP28 and SFP+ modules to be plugged into a QSFP28 port), NT200A01-8×10/2×40, NT80E3-2-PTP-8×10/2×40, NT40A01-4×10/1-SLB, NT40E3-4-PTP, NT20E3-2-PTP |
|
|
SFP |
NT40A01-4×10/1-SLB, NT40A01-4×1, NT40E3-4-PTP, NT20E3-2-PTP |
|
Monitoring parameters for NT SmartNICs
This table shows the most important SmartNIC parameters of which the NT SmartNICs provide monitoring.
Parameter | Mode of Operation |
---|---|
Link status | Ethernet link status per port |
PCB temperature | PCB temperature level and alarm |
FPGA temperature | FPGA temperature level and alarm Automatic over-temperature shutdown Note: Three FPGA temperature levels are significant:
Note: When the
LogToSystem parameter in the
ntservice.ini
file (see DN-0449) is set to
1, the warning messages are also logged in the system
log.
|
Time synchronization status | Status on SmartNIC time synchronization and loss of synchronization |
Fan speed | Speed of the cooling fan Note: An out-of-range fan speed
event is written to the hardware log if the fan rotates at a speed outside a
specific range. The event can be monitored from the application through the
API.
For NT200A02-SCC and NT200A01-SCC the low limit is 5264 RPM and the high limit is 7450 RPM. For NT200C01-SCC, NT100E3-1-PTP, NT80E3-2-PTP and NT80E3-2-PTP-8×10/2×40 the low limit is 4738 RPM and the high limit is 6566 RPM. For NT40A01-4×10/1-SLB, NT40A01-4×1, NT40E3-4-PTP and NT20E3-2-PTP the low limit is 4000 RPM and the high limit is 6000 RPM. |
Critical temperature | Temperature of critical components |
Power | Total power consumption |
Monitoring parameters for Intel® PAC with Intel® Arria® 10 GX FPGA
The Intel® PAC with Intel® Arria® 10 GX FPGA provides monitoring of FPGA temperature level with alarm and automatic shutdown as shown in this table.
Parameter | Mode of Operation |
---|---|
FPGA temperature | FPGA temperature level and alarm Automatic over-temperature shutdown Note: Two FPGA temperature levels are significant:
Note: When the
LogToSystem parameter in the
ntservice.ini
file (see DN-0449) is set to
1, the warning messages are also logged in the system
log.
|