Specifying PTP UTC Offset from Reference

Time-Stamping and Time Synchronization

Platform
Napatech SmartNIC
Content Type
User Guide
Capture Software Version
Link™ Capture Software 12.2

In this section

This section describes how to specify PTP UTC offset from reference.

PTP UTC offset from reference

The PtpUtcOffsetFromReference parameter specifies the UTC offset from the reference in seconds. This offset is only used if the PTP master does not provide a valid UTC offset value.

ntservice.ini code line

The syntax for the ntservice.ini code line specifying the PTP UTC offset from reference is:

'PtpUtcOffsetFromReference' '=' ( '–32767' | '–32766' |
 '–32765' | ... | '0' | '1' |  '2' | ... | '32767' )

Example:

PtpUtcOffsetFromReference=3

Default value

This table shows the default value.

Parameter Default Value
PtpUtcOffsetFromReference 0