In this section
This section describes how to specify the limit for when a SmartNIC is in NT-TS synchronization.
NT-TS in-synchronization limit
The TimeSyncNTTSInSyncLimit parameter specifies the range in ns in which a SmartNIC is considered to be in NT-TS synchronization. The NtTimeSyncGlobalStatus parameter in the information stream shows the status. An event is generated when the status changes.
Select a value for TimeSyncNTTSInSyncLimit according to the expected and acceptable stability of the reference.
ntservice.ini code lines
The syntax for the ntservice.ini code lines specifying the limit for when a SmartNIC is in NT-TS synchronization is:
'TimeSyncNTTSInSyncLimit' '=' ( '1' | '2' | '3' | ... | '0xFFFFFFFF' )
Example:
TimeSyncNTTSInSyncLimit=2500
Default value
This table shows the default value.
Parameter | Default Value |
---|---|
TimeSyncNTTSInSyncLimit | 5000 |