Install a SmartNIC in a Server

NT100A01-SCC Installation

Platform
Napatech SmartNIC
Content Type
Hardware Installation Guide
The SmartNIC is not hot-pluggable.
  1. Power off the server, and remove the server cover.
    Ensure that the power cable is unplugged from the server.
    CAUTION:
    Refer to the server documentation for correct procedure and for safety instructions.
  2. Remove the SmartNIC from the ESD bag.
    CAUTION:
    Observe the ESD precautions detailed in ESD Precautions when handling or placing the SmartNIC on a surface.
  3. Insert the SmartNIC in a vacant PCI Express ×16 connector, ensuring that it sits securely within the PCI Express connector.
  4. If the PCIe slot does not support 75 W, connect the optional auxiliary power connector to an additional power supply outlet (see Optional Auxiliary Power Connector).
  5. Secure the SmartNIC at the rear end of the server by fastening it at the top of the I/O bracket using the retention mechanism provided in the server, if applicable.
  6. Depending on the SmartNIC configuration, plug in the appropriate pluggable modules:
    • NT100A01-SCC to run at 4 × 25/10 Gbit/s: Plug in the desired SFP28 or SFP+ modules.
    • NT100A01-SCC to run at 4 × 10/1 Gbit/s: Plug in the desired SFP+ or SFP modules.

    See Plug In a Pluggable Module for more detailed instructions.

  7. Connect a network device via a fiber optic cable to the SmartNIC.
  8. Replace the server cover, and power on.
The SmartNIC is now ready to operate.