Time synchronization
Characteristic | Description |
---|---|
Time synchronization connectors |
External: Tyco Industrial Mini connector (see Tyco Industrial Mini connector) Internal: MCX female coax connector (see MCX-based inputs) |
Location |
|
Input considerations
The time synchronization input interfaces of the NT SmartNICs are supplied with limited protection.
The time synchronization inputs on the NT SmartNICs do not fully support NT-PPS time synchronization output signals.
When a time synchronization input is configured for PPS signals, the rising edge is interpreted as on time.
MCX-based inputs
This table specifies the time synchronization input interface for the MCX-based inputs on the NT SmartNIC (the internal inputs).
Mode | Type | Parameter | Value |
---|---|---|---|
Power off/ Interface off | – | Termination | 100 kΩ DC |
PPS mode | In | Termination | 50 Ω DC |
Rise/fall time | 0 – 30 ns | ||
Input levels | Rising edge, TTL levels | ||
Pulse width | 1 µs – 999 ms | ||
Current in clamping circuit | 130 mA @ 5 V input | ||
Out | Rise/fall | 0 – 10 ns | |
Output levels | Rising edge, TTL levels @ 50 Ω load | ||
Pulse width | 67 ms | ||
NT-TS mode | In | Termination | 50 Ω AC |
Rise/fall time | 0 – 30 ns | ||
Input levels | LVCMOS 2.5 V levels | ||
Pulse width | Proprietary NT protocol | ||
Current in clamping circuit | 130 mA @ 5 V input | ||
Out | Rise/fall | 0 – 10 ns | |
Output levels | LVCMOS 2.5 V levels | ||
Pulse width | Proprietary NT protocol |
Tyco Industrial Mini connector
Supports precision time protocol (PTP) over Ethernet with data transfers of 10 or 100 Mbit/s.
- PPS/TTL level in 50 Ω
- NT-TS
Available time synchronization cables
For information on available time synchronization cables, see DN-0186 on docs.napatech.com (the Napatech Documentation Portal).
Style Conventions
Bold typeface is used for names of, for instance, user interface elements and software components.
Italic typeface is used for replaceable text.
Monospaced typeface is used for code, commands and file names.