Install a SmartNIC in a Server

NT400D11-NEBS Installation

Platform
Napatech SmartNIC
Content Type
Hardware Installation Guide

About this task

The SmartNIC is not hot-pluggable.

Procedure

  1. Power off the server, and remove the server cover.
    CAUTION:
    Refer to the server documentation for correct procedure and for safety instructions.
  2. Remove the SmartNIC from the ESD bag.
    CAUTION:
    Observe the ESD precautions detailed in ESD Precautions when handling or placing the SmartNIC on a surface.
  3. Insert the SmartNIC in a vacant PCI Express ×16 connector, ensuring that it sits securely within the PCI Express connector.
  4. If the PCIe slot does not support 75 W, connect the optional auxiliary power connector to an additional power supply outlet (see Optional Auxiliary Power Connector Specifications).
  5. Secure the SmartNIC at the rear end of the server by fastening it at the top of the I/O bracket using the retention mechanism provided in the server, if applicable.
  6. Depending on the SmartNIC configuration, plug in the desired modules.

    See Plug In a Pluggable Module for more detailed instructions.

  7. Connect a network device via a fiber optic cable to the SmartNIC.
  8. Replace the server cover, and power on.
  9. Install the driver for the SmartNIC.
    For information on installing a Napatech driver, see:
  10. If the default image in the SmartNIC (the image in bank 0) is not the desired image, you must use the --switch command of the imgctrl tool to switch the SmartNIC to image bank 1, if this contains the desired image (see DN-0487). If the desired image is neither in bank 0 nor in bank 1, you must use the --program command of the imgctrl tool to upload the desired image to the SmartNIC (see DN-0487).

Results

The SmartNIC is now ready to operate.