Time synchronization
Characteristic | Description |
---|---|
Time synchronization connectors |
External: SMA female coax connector (see SMA female coax connector protocols) |
Location |
|
Input considerations
The time synchronization input interfaces of the NT SmartNICs are supplied with limited protection.
Warning: Connecting incompatible signal sources to NT time synchronization input
interfaces might damage the NT SmartNIC hardware.
When a time synchronization input is configured for PPS signals, the rising edge is interpreted as on time.
SMA female coax connector protocols
This table specifies the supported external SMA connector protocols.
Protocol | SMA 1 | SMA 2 |
---|---|---|
1PPS Output | Supported | Not supported |
1PPS Input | Supported | Supported |
10MPPS Output | Not Supported | Supported |
10MPPS Input | Not Supported | Supported |
MCX- and SMA-based I/O
This table specifies the time synchronization input interface for the MCX- and SMA-based inputs and outputs on the NT SmartNIC (the internal and external inputs, respectively).
Mode | Type | Parameter | Value |
---|---|---|---|
Power off/ Interface off | – | Termination | 100 kΩ DC |
Current in clamping circuit | 60 mA @ 5 V input Note: This only applies to external SMA-based inputs and not
to internal MCX-based inputs.
|
||
PPS mode | In | Termination | 50 Ω DC |
Rise/fall time | 0 – 30 ns | ||
Input levels | Rising edge, TTL levels | ||
Pulse width | 1 µs – 999 ms | ||
Current in clamping circuit | 130 mA @ 5 V input | ||
Out | Rise/fall | 0 – 10 ns | |
Output levels | Rising edge, TTL levels @ 50 Ω load | ||
Pulse width | 67 ms | ||
NT-TS mode Note: This only applies to internal MCX-based inputs and
not to external SMA-based inputs.
|
In | Termination | 50 Ω AC |
Rise/fall time | 0 – 30 ns | ||
Input levels | LVCMOS 2.5 V levels | ||
Pulse width | Proprietary NT protocol | ||
Current in clamping circuit | 130 mA @ 5 V input | ||
Out | Rise/fall | 0 – 10 ns | |
Output levels | LVCMOS 2.5 V levels | ||
Pulse width | Proprietary NT protocol |
Note: MCX connectors are not included in NT400D11-NEBS SmartNICs.
Available time synchronization cables
For information on available time synchronization cables, see DN-0186 on docs.napatech.com (the Napatech Documentation Portal).