Install a SmartNIC in a Server

NT50B01 Installation

Platform
Napatech SmartNIC
Content Type
Hardware Installation Guide

About this task

The SmartNIC is not hot-pluggable.

Procedure

  1. Power off the server, and remove the server cover.
    CAUTION:
    Refer to the server documentation for correct procedure and for safety instructions.
  2. Remove the SmartNIC from the ESD bag.
    CAUTION:
    Observe the ESD precautions detailed in ESD Precautions when handling or placing the SmartNIC on a surface.
  3. Insert the SmartNIC in a vacant PCI Express ×16 connector, ensuring that it sits securely within the PCI Express connector.
  4. Secure the SmartNIC at the rear end of the server by fastening it at the top of the I/O bracket using the retention mechanism provided in the server, if applicable.
  5. Plug in the desired SFP28 or SFP+ modules.

    See Plug In a Pluggable Module for more detailed instructions.

  6. Connect a network device via a fiber optic cable to the SmartNIC.
  7. Replace the server cover, and power on.
  8. Install the driver for the SmartNIC, see DN-0379.

Results

The SmartNIC is now ready to operate.