Time Synchronization Connector Specifications

NT50B01 Installation

Platform
Napatech SmartNIC
Content Type
Hardware Installation Guide

Time synchronization

Table 1. Time synchronization connectors
Characteristic Description
Time synchronization connectors External: SMA female coax connector (see SMA-based I/O)
Location Page-1 Sheet.4 Sheet.2 External SMA time synchronization connector Optional external SMA time synchronization connector Sheet.3

Input considerations

The time synchronization input interfaces of the SmartNICs are supplied with limited protection.

Warning: Connecting incompatible signal sources to time synchronization input interfaces might damage the SmartNIC hardware.

When a time synchronization input is configured for PPS signals, the rising edge is interpreted as on time.

SMA-based I/O

This table specifies the time synchronization input interface for the SMA-based input and output on the NT SmartNIC (the external input).

Table 2. SMA-based inputs and outputs
Mode Type Parameter Value
Power off/ Interface off Termination 100 kΩ DC
Current in clamping circuit 60 mA @ 5 V input
PPS mode In Termination 50 Ω DC
Rise/fall time 0 – 30 ns
Input levels Rising edge, TTL levels
Pulse width 1 µs – 999 ms
Current in clamping circuit 130 mA @ 5 V input
Out Rise/fall 0 – 10 ns
Output levels Rising edge, TTL levels @ 50 Ω load
Pulse width 67 ms

Available time synchronization cables

For information on available time synchronization cables, see DN-0186.