Arista time-stamp frames
This only applies to the following SmartNICs.
- NT400D11 SmartNICs running on the 2 × 100 Gbit/s test and measurement image
- NT200A02 SmartNICs running on the 2 × 100 Gbit/s test and measurement image
- NT200A02 SmartNICs running on the 2 × 40 Gbit/s test and measurement image
The frame decoder identifies an Arista time-stamp frame if the following conditions are
met:
- The EtherType field is 0xD28B.
- The SubType field is 0x0001.