Setting the Time Synchronization Clock Adjustment Mode

Time-Stamping and Time Synchronization

product_line_custom
IntelĀ® PAC
Napatech SmartNIC
category
User Guide

In this section

This section describes how to set the time synchronization clock adjustment mode.

Time synchronization clock adjustment mode

The TimeSyncClockAdjustmentMode parameter specifies the time synchronization clock adjustment mode and that the PTP PHY limits the clock rate change to 2,000 ppm.
Note: The parameter is present for legacy compatibility.

ntservice.ini code line

The syntax for the ntservice.ini code line setting the time synchronization clock adjustment mode is:

'TimeSyncClockAdjustmentMode' '=' '2'

Example:

TimeSyncClockAdjustmentMode=2

Default value

This table shows the default value.

Parameter Default Value
TimeSyncClockAdjustmentMode 2